Data Centres

We operate our Windows Servers out of 2 datacentres in London

Stratford Data Centre

Webspeed's servers are located in a state-of-the-art raised floored datacentre in Stratford, London. The facility offers complete redundancy in protected power, HVAC, fire suppression, network connectivity and on-site manned security. The facility takes power feeds from multiple power grids, distributed via MGE UPS battery backup power and three 2.5 MVA Caterpillar diesel generators to backup primary power source with 48-hour on-site fuel storage supported by continuous refuelling contracts. Our Libert HVAC systems are configured to provide cooling redundancy in a temperature controlled environment. Fire suppression includes a dry pipe pre-action system with VESDA (Very Early Smoke Detection Apparatus).

sta.lon - Stratford, London

  • 7,000 sq.ft facility
  • 6,000 sq.ft of raised floor
  • (5) 26-ton Libert AC units
  • Dry pipe pre-action sprinkler system
  • Very Early Smoke Detection Apparatus (VESDA)
  • 4500+ amps of input power
  • (2) 550KVA MGE UPS units
  • (3) 2.5 MVA Caterpillar diesel generators
  • Three point fibre duct enternace
  • BMS monitoring software for all data center infrastructure

Network Infrastructure

Our network utilises Juniper M Series routers at the border, Cisco Catalyst 6500 series and Foundry BigIron 10G switches in our core switching layer and Cisco 3550/3750 series switches in our distribution layer. At the customer layer we utilize Cisco 3500 and 2950 series switches.

Juniper M Series border routers
Cisco Catalyst 6500 Series and
Foundry BigIron 10G core routing switches
Cisco 3750 distribution switches 

 

RedBus London Data Centre

A 18,400 square foot IDC (Internet Data Center) facility in London – the hub of telecommunications and Internet connectivity for the United Kingdom. Housed in the prestigious Redbus London Interhouse "Meridian Gate", this multi-million pound facility is seismically designed to include the latest gas-based fire protection systems, specialised heat and smoke sensors, raised flooring, scalable power for future expansion, 24x7 technical support 365 days a year and unmatched levels of security.

The spacious facility features state-of-the-art fiber optics and a redundant self contained cooling system. With 2.5 MVA of UPS conditioned power, and 2 x 1800 kva Generators, the facility can be separated from city water and power services and still remain fully operational for up to 28 days - the backup generators alone could power a city of 20,000 people.

Physical Security
All Redbus Interhouse datacentres feature totally comprehensive 24x7 security to keep our equipment 100% safe. This means our customers have the protection of security barriers, 24x7x365 monitoring by on-site personnel to include visual verification of all persons entering the building, CCTV video camera surveillance and a security breach alarm provides the control room with information.

Access
Access to the buildings, data floors and individual area’s are via individually programmed Proximity Access Cards (PAC), usage of the PAC is logged centrally by time and date. The cards cannot be used by anyone else, whenever you swipe your card tag over the sensors to gain access to the building, your digital photograph will be displayed on our security systems which are continuously monitored by our on-site technicians. The technicians will then verify the information and only when satisfied, allow access.

Power
All Redbus Interhouse facilities are built to at least an N+1 standard; put simply, this means that if two generators are required to provide non-stop power, then there’ll be three installed. So rather than guaranteeing 99.99% power availability, the guarantee is 100%.

Fire Detection/Suppression
Very Early Smoke Detection Apparatus (VESDA) is installed in every facility. These highly sensitive aspirating smoke detectors are linked to the Building Management system which is monitored continually from a network operations centre, provide very early detection to help avoid fire, loss and business disruption. This is coupled with a gas based fire retardant that is environmentally friendly, to put out fires instantly, without damaging equipment.

Air Conditioning
To ensure optimum performance, all data floors are maintained at a constant 21°C ± 2°C and relative humidity is kept at 50% ± 10%. Both are continually monitored via the BMS.

Building Management System (BMS)
All Redbus Interhouse facilities operate computerised building management systems that monitor and remotely operate sensors covering electrical, mechanical, fire detection and leak detection systems.

 

 

 

Ask a Question
 If you have any questions about our services then please complete the form below, replies are
 generally very quick however please allow 24 hours, thanks.
 Your current page location is: www.webspeed.co.uk/company/datacentre.asp

* Name
Company Name
Phone Number
 * Email
* Question
* Preferred Reply
 * Security Code
Please type the code in the box below, if you find it difficult to read click "Load New Code"
Code Image - Please contact webmaster if you have problems seeing this image code Load New Code
 
  * = Required Field

The 1st Choice for Reliable Website Hosting - www.webspeed.co.uk

Copyright © 2008 Touch IT Solutions. All rights reserved
All prices are excluding VAT at 17.5% unless otherwise stated
Terms & Conditions | Privacy Statement | Contact Us

For DIY web design see our webkeeper site:  Online Website Builder